Show simple item record

dc.contributor.authorBurgos, F.
dc.contributor.authorMengelle, D.E.
dc.contributor.authorOzols, A.
dc.contributor.authorFernandez, C.
dc.contributor.authorAutorino, C.M
dc.date.accessioned2019-11-21T21:35:04Z
dc.date.available2019-11-21T21:35:04Z
dc.date.issued2016-11-03
dc.identifier.citationBone & Joint ResearchVolume 5, Issue 11, November 2016, Pages 531-537en_US
dc.identifier.issn2046-3758
dc.identifier.urihttps://riu.austral.edu.ar/handle/123456789/784
dc.description.abstractObjectives Studies reporting specifically on squeaking in total hip arthroplasty have focused on cementless, and not on hybrid, fixation. We hypothesised that the cement mantle of the femur might have a damping effect on the sound transmitted through the metal stem. The objective of this study was to test the effect of cement on sound propagation along different stem designs and under different fixation conditions. Methods An in vitro model for sound detection, composed of a mechanical suspension structure and a sound-registering electronic assembly, was designed. A pulse of sound in the audible range was propagated along bare stems and stems implanted in cadaveric bone femurs with and without cement. Two stems of different alloy and geometry were compared. Results The magnitudes of the maximum amplitudes of the bare stem were in the range of 10.8 V to 11.8 V, whereas the amplitudes for the same stems with a cement mantle in a cadaveric bone decreased to 0.3 V to 0.7 V, implying a pulse-attenuation efficiency of greater than 97%. The same magnitude is close to 40% when the comparison is made against stems implanted in cadaveric bone femurs without cement. Conclusion The in vitro model presented here has shown that the cement had a remarkable effect on sound attenuation and a strong energy absorption in cement mantle and bone. The visco-elastic properties of cement can contribute to the dissipation of vibro-acoustic energy, thus preventing hip prostheses from squeaking. This could explain, at least in part, the lack of reports of squeaking when hybrid fixation is used. Cite this article: F. J. Burgo, D. E. Mengelle, A. Ozols, C. Fernandez, C. M. Autorino. The damping effect of cement as a potential mitigation factor of squeaking in ceramic-on-ceramic total hip arthroplasty.en_US
dc.language.isoenen_US
dc.publisherBritish Editorial Society of Bone and Joint Surgeryen_US
dc.subjectSqueakingen_US
dc.subjectDampingen_US
dc.subjectCementen_US
dc.titleThe damping effect of cement as a potential mitigation factor of squeaking in ceramic-on-ceramic total hip arthroplastyen_US
dc.typeArticleen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)